top of page
Air Quant
state of the air
see with your eyes
Fits in your pocket.
small and simple
Analysis time 60 seconds.
We provide our own solutions for environmental monitoring through component detection and analysis such as drinking water safety, indoor environmental safety, and food safety, and customized solutions for component measurement and analysis required by various industrial partners.
Air Quality
Monitoring Solution
14 items of the surrounding environment in which you live
Accurate real-time measurement.
Simple rapid monitoring
and management analysis.
Check out a total of 14 harmful item data, including fine dust, organic compounds, temperature and humidity, measured and analyzed in real time, and protect yourself from danger.
sampling
Water Scanner Analysis
Data collection and transmission
in a central database
data collection
Real-time central water quality data
Monitoring map provided
Water scanners can be installed throughout water resources to collect real-time water composition data to create a water quality monitoring solution. And it will help predict the spread of pollutants in the future through AI data analysis.
All sensors attached to the AirQuant are being measured in real time.
Therefore, you can check all the information with your eyes and provide notifications according to the measured information.
Indoor air condition monitoring provide results
Easy real-time data analysis and quick response
Check on kiosks and electronic boards in government offices and public facilities.
various devices and Dedicated APP
light_Blink
light
light_Blink
1/2
Blinking green light
Connecting to the network.
Static green light
Network connection complete.
/ Operation.
Blinking white light
Bluetooth connecting.
Static white light
Data transfer complete.
Blinking red light
System error.
Static blue light
Network connection error.
More precisely
individual sensors
Separate sensors make maintenance and repair easy. Each sensor attached for 14 items measures in more detail. On top of that, individual detachment and attachment are possible, relieving concerns about future replacement and repair. Like this, Air Quant makes you feel safe about your life.
Sensor monitoring items.
Temperature
Humidity
carbon dioxide
fine dust
Total Volatile Organic Compounds (TVOC)
Chemicals (SO2, NO2, CO)
Unit
Range
Accuracy
℃
-40 ~ 125
± 0.2
%RH
0 ~ 100
± 2
Lx
1 ~ 20,000
± 10%
hPa
300 ~ 1,250
±0.08 (equiv to 0.66m)
μg/m3
0 ~ 1,000
± 10%
ppm
400 ~ 10,000
±(30+3%)
ppm
0 ~ 1,000
± 2%
ppm
0 ~ 20
± 3%
ppm
0 ~ 5
± 5%
ppm
0 ~ 60
± 5%
Sensitivity : -18 dBV/Pa
SNR : 63dBA
℃
-70 ~ 380
0.5
Sensor
Temperature
Humidity
Illuminance
Air Pressure
Particulate Matter
Carbon Dioxide
CO2
Carbon Monoxide
CO
Sulfur Dioxide
SO2
Nitrogen Dioxide
NO2
TVOC
Total volatile organic compounds
Noise
Early Fire Detection
Sensor list
Unit
Safety
●
Caution
●
Warning
●
Temperature
℃
22 ~ 26
18 ~ 21
27 ~ 29
< 17
> 30
Humidity
%RH
35 ~ 55
25 ~ 35
55 ~ 70
< 25
> 70
Particulate Matter
PM2.5
μg/m3
< 35
36 ~ 75
> 76
Particulate Matter
PM10
μg/m3
< 80
80 ~ 150
> 151
Carbon Dioxide
CO2
ppm
< 1,000
1,000 ~ 1,500
> 1,500
Carbon Monoxide
CO
ppm
< 5
6 ~ 50
> 51
Sulfur Dioxide
SO2
ppb
< 8
8 ~ 38
> 39
Nitrogen Dioxide
NO2
ppb
< 20
20 ~ 100
> 101
TVOC
Total volatile organic compounds
ppb
< 2,000
2,000 ~ 3,000
> 3,000
HVAC operation system interworking
Create a pleasant indoor environment by adjusting the temperature, humidity, and cleanliness.
Analyze the causes of water pollution such as water pipes, water supply safety, and tank conditions
beverage factory
It checks in real time whether the beverage is contaminated during the beverage manufacturing process.
cup holder
The occupant inspects the safety of the drink and Check your drinking habits
water purifier
Check the safety of drinking water and notify the filter replacement time
Infinite scalability
in simplicity.
Air Quant's PoE module and wireless AP can operate with low power, and wireless networks can be used without additional equipment and connections between devices even in large spaces.
PoE
LAN - Low power 5V operation of cable
wireless AP
Provides massive scalability and wireless networks
indoor air quality
management law.
Enforcement 2021. 4. 1.
(Act No. 16307, 2019. 4. 2. partially amended)
Ministry of Environment 2020. 04. 03
Revision of indoor air related laws
<Ultra-fine dust (PM 2.5) management standards for each facility>
Management standards General multi-use facilities (underground stations, large-scale stores, etc.): 50㎍/㎥
Sensitive class use facilities (daycare centers, medical institutions, etc.): 35㎍/㎥
Public transportation vehicle: 50㎍/㎥ (newly established)
In case of violation, a fine for negligence, an order for improvement
Mandatory measurement of indoor air quality in public transportation vehicles (urban railroads, railroads, intercity buses)
New recommendation standard for ultrafine dust (PM2.5) in public transportation vehicles
Mandatory installation of automatic indoor air quality measurement equipment in underground stations (Enforced on April 1. 2021)
Children's play facilities over 430 m², home/cooperative daycare center law applied
installation example
Clean air is the key to protecting the Earth.
PiQuant is leading the field of 'analysis' essential for ESG management or energy efficiency, and has been selected as one of the Green New Deal companies top 100 and innovative companies top 100. we developed real-time IoT air quality monitoring device for improve the environment in line with environmental regulations and guidelines through indoor air quality measurements in response to global concerns about fine dust and air pollution issues. also, contributing to creating a better world based on innovative tech.
Product Tech Spec.
Size and Weight
Height :
6.02 inches
(153 mm)
Depth :
2.36 inches
(60 mm)
Width :
6.02 inches
(153 mm)
Weight :
21.16 ounces (600 grams)
Network
Ethernet
Wi-Fi
Bluetooth
HVAC linkable
Wireless Broadband 2.4Ghz
Sensors
Basic measurable target
Temperature
Additional measurement targets (separately)
Humidity
noise
TVOC
Installation and Management
Maintenance and installation work required
10³ CFU/ml (E.coli)
One
Power
DC 5V
Power over Ethernet (PoE)
Certification
Fine dust simple meter 1st grade
RoHS, CE, KC certification
ElectroMagnetic Compatibility (EMC TEST) EN 62311:2008
Broadband transmission systems EN 300 328 V2.2.2
bottom of page